AUTHORIZATION
Home > Humidifiers > Karl Big air humidifier
Karl Big air humidifier
Humidifiers

Karl Big air humidifier

The humidifier with superpower
Availability item sold out
Price 279.00
329.00

Art: Article K-006

 Efficient humidification with low power consumption
 Top filling during operation
 All functions can be controlled via smartphone app
 Room size 150m²

Description
Technical Data
FAQ
Manual

Important information for the buyer before making a purchase!

Before making a purchase in our online store, we invite the buyer to carefully familiarize themselves with the range of air humidifiers and their technical parameters. Each air humidifier has different power, designated room area (m²), and volume (m³), which directly affects the efficiency of the device. During the heating season, especially in the cold time of the year, intense room heating causes the air to become too dry. To ensure effective air humidification, buyers are advised to choose a humidifier with a power that is approximately double the actual room size. This condition ensures the humidifier's ability to maintain comfortable humidity even in the coldest and driest rooms. Please consider the following important conditions:

the air humidifier is intended for use in enclosed spaces;
during the operation of the device, windows and doors must be closed;
the air humidification effect is not immediate.
A stable and complete result is usually achievable only after 96 hours if the device operates in continuous mode and is used according to the manufacturer's instructions. Proper selection of the humidifier and appropriate operation ensures an optimal microclimate in the room, comfort in use, and effective long-term device operation.

Despite its low energy consumption, when the Karl Big air humidifier starts, it quickly humidifies spaces up to 150 m². Whether it is a large office, spacious bedroom, or relaxation area, the vaporizer provides any large space with healthy and pleasant air humidity. Its elegant design looks bright and fresh, fitting perfectly in any living space. To ensure undisturbed sleep, the LED lighting function of the Karl Big air humidifier can be adjusted or turned off completely.

System
Evaporative
Evaporator
Accessories (included in the set)
1 water reservoir, 2 humidifier filters
1 water reservoir, 4 humidifier filters
Room area m²
100
150
Room size m³
250
375
Power
690 g/h
1100 g/h
Power level
4
4
Colors
Black
Black
Water tank volume, ltr
4
10
Weight, kg
2.5
4.6
Dimensions, mm
296 x 304 x 212
502 x 335 x 242
Gross, kg
3.65
6.2
Packaging, mm
345 x 370 x 260
550 x 390 x 290
Electricity consumption, W
1.4-30
2.4-40
Noise level
27-59 dB(A)
27-60 dB(A)
What is the best way to fill my Karl big with water?

Ideally, you fill your Karl big using the top filling opening. Of course, you can also fill Karl big at the tap, but then you must be extra careful that no water spills during transportation.

Why is the humidity not rising while Karl big is switched on?

Set the output to the highest level. For the room size to be right, not only the room height (standard 2.5 m) but also whether or not the doors to the room are closed is a determining factor. If the doors to the room are left open, the adjacent rooms will also be included in the total area. If the relative humidity is low (below 35%), the humidity will not increase immediately. That is because the floors, furniture and walls absorb the moisture first before it ends up in the air. It can take up to two weeks for everything to absorb sufficient moisture for the humidity to start rising. As long as you keep having to top up the water regularly, your Karl big is working properly. I f the humidifier filters are more than 2 months old or the upper part is hard and no longer saturated with water, the filters should be replaced.

Karl big humidifier filters

For the hygienic and optimal use of the humidifier, the humidifier filter should be replaced at least every two months. If you continue to use the humidifier filter for longer than this, on the one hand the humidification output may deteriorate significantly and on the other, the antibacterial action of the filter can no longer be guaranteed. You can generally purchase humidifier filters from the place where you bought your device. The filter change indicator has to be reset manually after changing the filters. Discolouration which is slightly yellowish or brownish is normal. Discolouration is caused by the substances in the mains water or the air. The poorer the water quality, the quicker the humidifier filter will become discoloured. Although this does not look pleasant, it is harmless as long as it is not due to mould. The discolouration will not affect the performance of your humidifier either. If you have not been using the humidifier filter for very long, you can rinse it thoroughly, turn it over and reuse it. If the humidifier filter is more than 2 months old, we recommend that you replace it. It is also possible for the top part of the humidifier filters to become hard. During the evaporation process, the lime present in the water is collected in the humidifier filter as limescale. The harder the water, the quicker the humidifier filter will become hard. If you use water from a water softener which operates based on the principle of ion exchange, salt may collect in the humidifier filter rather than limescale. If you have been using the humidifier filter for less than 2 months, you can rinse it thoroughly with water, turn it over and put it back again. It is possible that you may notice an odour after you have turned over the humidifier filter depending on how contaminated the filter is by constituents in the air or the water. If your Karl big or the humidifier filters smell unpleasant, there may be various reasons for this: water and air quality, a worn-out filter or even the fact that you have not used your Karl big for a long time and he has still water in his tank. In any case, we recommend that you clean and descale the device thoroughly. If you have been using the filter for less than 2 months, you can rinse it thoroughly with cold, clean water, turn it over and continue to use it.

Why does my external measuring device display a different humidity to Karl big?

It may be that your external hygrometer and Karl big are measuring different values because the devices have been positioned in different places (heights) in the room. Different humidity values will be measured depending on the air flow and temperature in each case. A tolerance of +/- 5 % is normal depending on the type of device. Karl big measures the humidity levels best if he is positioned in the middle of the room so that the room air can flow towards the sensor as freely as possible. If that is not possible, we recommend positioning Karl big against the wall, with a clearance of at least 30 cm. Under no circumstances should Karl big be “hidden” in a corner of the room or behind a sofa/piece of furniture because this can have a negative effect on humidity measurement as well as humidification efficiency.

Auto mode

Karl automatically selects the appropriate humidification level in auto mode to reach and maintain the desired humidity quietly and efficiently.

Easy handling

The 4-liter water container can be easily filled through a flap opening on the top, even during operation. When the water container is empty, Karl switches off automatically.

Simple operation

All functions of humidifier Karl can be conveniently controlled on the unit or via Wi-Fi using the Stadler Form app - including monitoring of the current humidity. This ensures an optimal indoor climate at home even when you are on the move.